Steel truss
Steel truss: pick a layout, span and pitch, and get chords and webs sized and checked to AISC 360-22, with ASCE 7-22 load combinations, for roof and floor trusses.
Inputs of the steel truss #
- Roof or floor, truss type: roof trusses offer 18 layouts, floor trusses the parallel-chord ones.
- Geometry: span between the outer bearing lines, pitch (rise in 12), heel height, depth on parallel chords, flat length on a hip, rise on a bowstring, room width and height on an attic, overhangs, panels (Auto: about 6 ft on a pitched truss, about 1.5 depths on parallel chords; a count the layout cannot have snaps to the nearest one and the results say so).
- Supports: pin, roller or none at each end, intermediate supports (moved to the nearest chord joint, and the results say where), bearing on the bottom or top chord of a parallel-chord truss.
- Loads: area loads in psf times the truss spacing: top chord dead, roof live, snow, unbalanced snow, floor live, bottom chord dead and live. Live load on half the span as well (ASCE 7-22 4.3.3, on by default, because web forces reverse under it). Wind rows (pressures normal to the top chord from your wind analysis, each checked from both directions), total horizontal seismic, SDS for the vertical effect, and point loads anywhere on a chord, also between panel points.
- Members: Size the members automatically is on by default: at every calculation the lightest section of each group that passes is chosen. Turn it off to enter the sections and have them checked as they are.
- Bracing: what holds each chord out of plane, and the webs: as needed (a compression web that fails unbraced gets a lateral brace at mid-length before anything is upsized, and the results, schedule and sheet name it), none, or every web. These are your judgment as engineer of record, and the braces themselves are not designed.
- Members with their own section: a mark from the schedule and a section, for one heavy web or chord panel. The rest keep the section of their group.
- Serviceability: live and total deflection limits as span / n, and the horizontal movement limit at a roller.
Auto-design varies the top chord, bottom chord and web sections, lightest first, within the given families, and fixes the result (it turns automatic sizing off). It never changes the geometry, loads, bracing or code options.
Analysis. A plane frame, first-order, with chords continuous over the panel points and pinned at heels and pitch breaks, and webs pinned at both ends, or every panel point pinned if you choose. Loads between panel points are carried in chord bending, so a chord has axial force and bending together. Every load case is solved once and combined with ASCE 7-22 2.3.1 or 2.4.1 (and 2.3.6 or 2.4.5 with seismic). Deflections always use the ASD combinations.
- Sections: W, WT, double angle, HSS or pipe; the strong axis lies in the plane of the truss, and a WT or double angle has its stem or web legs toward the webs. Fy and Fu by family. Net area An/Ag and shear lag U are your inputs because the end connection is not designed. Double-angle connector spacing and type (AISC 360-22 E6).
Checks performed #
| Check | Basis |
|---|---|
| Tension yielding, rupture | AISC 360-22 D2 |
| Compression | E3, E4 (flexural-torsional of WT and double angles), E6 (built-up), E7 (slender elements) |
| Flexure, each sign | F2, F7, F8, F9, F10.3 (a stem or web leg in compression is much weaker) |
| Shear | Chapter G |
| Axial + bending | H1.1, with B1 of Appendix 8 at every station |
| Deflection | Your limits, IBC Table 1604.3 |
| Slenderness | E2 and D1 user notes, advisory |
The report prints the steps of the governing member of each group and lists every member in the schedule. Turn on Report every member step by step, under Serviceability, to print every member.
Limitations of the steel truss #
- Connections are not designed. Gussets, welds, bolts, splices, heel joints and anchorage (ILX Connection covers gussets), block shear. The forces in every member at every joint are listed for that design.
- One section each for the top chord, bottom chord and webs, apart from the members you give their own.
- One lateral brace per web at most, at mid-length.
- Work lines meet at the joints: joint eccentricity and secondary moments are not modeled. First-order analysis, with moments amplified member by member where the standard does so.
- Gable-end, gambrel, piggyback and unequal-pitch layouts are not generated. Use the 2-D truss analysis for any other geometry.
- Ponding, fire, floor vibration, system bracing design, wind pressure calculation and trusses carrying other trusses (use point loads) are outside this calculation.
- Single angles in compression (E5) are not offered.
Verification examples #
Verification status: 39 values compared in 9 examples (8 published, 1 hand calculations from the cited equations): 39 within tolerance, 0 recorded deviations. Code basis: not determined. The code is cited, but no record shows a section-by-section read for this module.
These results carry the label "Preview: not yet verified, do not rely on these results" on the screen, in the report and on the sheet. The frame solver is checked against closed-form beams and the pin-jointed solver. Member strengths run through the module against AISC Design Examples v16.0 D.3, D.6, E.5, E.6, E.7 and F.10, with hand statics for the forces. The combined check has no published example, and no published complete truss is on file.